Skip to main content
All Disciplines cover
NBC 2016 PART 4 FULL SPECTRUM
/REGULATORY: IS & NBC MATRIX

Engineered hardware. System verification.

Turnkey hydraulic risers, addressable detection topologies, and perimeter command nodes for mission-critical Indian infrastructure.

Scope:All Disciplines15 systems
Showing 15 engineered systems
Automatic Glass-Bulb Sprinkler Network
IS 15105
Fire Fighting

Automatic Glass-Bulb Sprinkler Network

Rapid-response ceiling glass bulb sprinklers coupled with alarm check valves, pressure switches, and riser manifolds.

68°C rating · 1/2" NPT · 7–12 bar pressure
Intelligent Optical Smoke & Heat Detector
IS 2189
Fire Alarm

Intelligent Optical Smoke & Heat Detector

Microcontroller-driven optical sensor chamber providing dual-wavelength infrared analysis and drift compensation.

2-wire addressable loop · LED 360° beacon
4K Industrial AI Perimeter Dome Camera
BIS / CE
CCTV Surveillance

4K Industrial AI Perimeter Dome Camera

Heavy-duty IK10 vandal-resistant dome camera with a 4K ultra-low-light optical sensor and embedded perimeter AI analytics.

8MP 4K · 30m Smart IR · IP67 / IK10
Oblique Landing Fire Hydrant Valve
IS 5290
Fire Fighting

Oblique Landing Fire Hydrant Valve

Oblique-pattern gunmetal landing valve with instantaneous female coupling, hydrostatically tested to 21 bar for internal riser terminations.

63mm instantaneous · 21 bar test pressure
Industrial Main & Standby Fire Pump Skid
IS 3844 / TAC
Fire Fighting

Industrial Main & Standby Fire Pump Skid

Multi-stage centrifugal fire pump driven by a direct-injection diesel engine with automatic crank failover controllers.

2,280 LPM · 7 bar head · Auto battery crank
Hydraulic Deluge Valve Control Trim
IS 15105 / TAC
Fire Fighting

Hydraulic Deluge Valve Control Trim

Fast-acting diaphragm deluge valve with solenoid control trim for high-hazard occupancy protection.

DN100 / DN150 flange · 16 bar working · Solenoid trim
Intelligent Addressable Manual Call Point
IS 2189
Fire Alarm

Intelligent Addressable Manual Call Point

Surface-mount addressable manual call point with resettable frangible element and integrated status LED.

Resettable test key · Loop powered
Multi-Criteria Thermal & Optical Node
IS 2189 / EN 54
Fire Alarm

Multi-Criteria Thermal & Optical Node

Combined rate-of-rise thermal and dual-wavelength optical sensing node for critical, dust-controlled facilities.

Dual NTC thermistors · 45µA quiescent · Soft addressed
Industrial Multi-Tone Sounder Beacon
IS 2189 / EN 54-3
Fire Alarm

Industrial Multi-Tone Sounder Beacon

Industrial multi-tone evacuation sounder with xenon strobe for plant rooms and process floors.

105 dB(A) at 1m · IP65 rated · 32 selectable tones
Biometric Optical Access Terminal
CE / FCC
Access Control & Security

Biometric Optical Access Terminal

Vandal-resistant brushed-metal optical biometric terminal for high-throughput entry control.

0.2s matching · Wiegand / OSDP / IP interface
Thermal AI Dual-Spectrum PTZ Node
ONVIF S/G
CCTV Surveillance

Thermal AI Dual-Spectrum PTZ Node

Dual-spectrum PTZ perimeter node pairing an uncooled thermal array with 36× optical zoom tracking.

640x512 uncooled thermal · 36x optical zoom · IK10
ABC Stored Pressure Dry Powder (6kg)
IS 15683
Extinguishers & PPE

ABC Stored Pressure Dry Powder (6kg)

Stored-pressure ABC dry-powder extinguisher with a MAP-90 charge for Class A, B, C and electrical risks.

6kg capacity · 43A 233B rating · EPDM hose
High-Pressure CO2 Cylinder Unit (4.5kg)
IS 2878
Extinguishers & PPE

High-Pressure CO2 Cylinder Unit (4.5kg)

Residue-free carbon dioxide extinguisher engineered for live electrical switchgear and server-rack suppression.

4.5kg CO2 · 250 bar test pressure · Insulated horn
Statutory Form 'B' Bi-Annual AMC Contract
MFS Act 2006
AMC & Compliance

Statutory Form 'B' Bi-Annual AMC Contract

Bi-annual Form 'B' statutory maintenance contract with quarterly physical testing and municipal filing.

Twice-yearly certification · Documented service records
Quarterly Riser & Pump Flow Audit
IS 13039 / NBC
AMC & Compliance

Quarterly Riser & Pump Flow Audit

Scheduled riser pressure maintenance, gland packing service, and diesel failover auto-crank verification.

Hydrostatic line audit · Flowmeter calibration · Form B